Skip to content
Thursday, 26 November 2026
Technology

Strain Gauges: How They Work, Types and Where You Meet Them

A plain-English guide to strain gauges: how a foil grid measures stretch, why it needs a Wheatstone bridge, the main types, where you meet them and the British part of their history.

Strain Gauges: How They Work, Types and Where You Meet Them

Short answer: a strain gauge is a tiny sensor, usually a zig-zag of metal foil on a thin plastic backing, that is glued to a part and measures how much that part stretches or squeezes. When the part stretches, the foil gets longer and thinner and its electrical resistance rises; when it is compressed, the resistance falls. The change is minute (a fraction of an ohm), so the gauge is wired into a Wheatstone bridge, a circuit first described by the British scientist Samuel Hunter Christie, which turns it into a measurable voltage. Strain gauges sit inside your bathroom and kitchen scales, motorway weighbridges, aircraft test rigs and bridge-monitoring systems, and a single foil gauge costs from about £9 from UK electronics suppliers.

Last checked: 26 November 2026. Technical figures are standard textbook values for metal foil gauges; bridge outputs are calculated from the ideal formula. Prices are from UK electronics supplier listings in November 2026 and change often. History is from published histories of the strain gauge and the Wheatstone bridge.
1938
first bonded wire strain gauge
≈ 2
gauge factor of a foil gauge
120 / 350 Ω
the standard resistances
From £9
for one foil gauge in the UK

What Is Strain, and Why Measure It?

Strain is how much something deforms compared with its original size: the change in length divided by the original length. It has no units, and because the numbers are so small, engineers use microstrain (µε), millionths of a unit. A 1-metre steel bar stretched by 1 millimetre has a strain of 1,000 µε.

Strain matters because, for most metals in normal use, it is directly linked to stress, the load the material is carrying. For steel, with a stiffness (Young’s modulus) of roughly 200 GPa, 1,000 µε corresponds to about 200 megapascals of stress. So if you can measure strain, you can work out the force on a beam, the weight on a scale, the torque in a shaft or how hard a wing is working, without cutting anything open. That is the whole point of a strain gauge.

Close-up of a foil strain gauge bonded to a metal surface with its lead wires soldered on
A foil strain gauge bonded to a metal part. The fine zig-zag grid is the sensing element; the wider pads are where the leads are soldered. Photo: Cristian V., Wikimedia Commons, CC BY 4.0.

How a Strain Gauge Works

The physics is simple. The resistance of a wire depends on its length and its cross-section: a longer, thinner wire has more resistance. Bond a fine metal grid firmly to a surface and it has to follow that surface exactly. Stretch the surface and the grid lines lengthen and narrow, so resistance goes up. Compress it and resistance goes down. Lord Kelvin reported in 1856 that metals change their resistance when strained; it took until the 1930s for anyone to turn that into a practical sensor.

A typical modern gauge has these parts:

  • The grid: a zig-zag of very thin metal foil, most often a copper-nickel alloy called constantan. The long lines all run one way, so the gauge is sensitive along that direction and almost blind across it.
  • The carrier: a thin film of polyimide or epoxy that insulates the grid and is glued to the part.
  • Solder tabs: the wider pads at one end where the lead wires attach.
  • Alignment marks: small marks on the carrier so you can line the gauge up with the direction you want to measure.

The sensitivity of a gauge is its gauge factor: the fractional change in resistance divided by the strain. For constantan foil it is about 2. That means a standard 350-ohm gauge at 1,000 µε changes by just 350 × 2 × 0.001 = 0.7 ohms. You cannot measure that reliably with a cheap multimeter, which is why the bridge circuit matters.

The Wheatstone Bridge: Turning Tiny Changes into a Signal

A Wheatstone bridge is four resistors arranged in a diamond, with a steady voltage (the excitation) across one diagonal and a voltmeter across the other. When all four arms are balanced, the output is zero. Replace one or more arms with strain gauges, and any strain unbalances the bridge and produces a small output voltage, measured in millivolts.

It is a very British piece of kit. Samuel Hunter Christie, a mathematician at the Royal Military Academy in Woolwich, published the circuit in 1833. Charles Wheatstone described it in a lecture in 1843, crediting Christie, but it is Wheatstone’s name that stuck.

ArrangementActive gaugesOutput (5 V, 1,000 µε, GF 2)Typical use
Quarter bridge1About 2.5 mVSimple tests; cheapest, but most affected by temperature
Half bridge2About 5 mVBending beams; one gauge in tension, one in compression
Full bridge4About 10 mVLoad cells, torque sensors and pressure transducers
Line chart of strain gauge bridge output against strain for quarter, half and full bridges at 5 volts
At 5 V excitation and 2,000 microstrain, a quarter bridge gives about 5 mV, a half bridge 10 mV and a full bridge 20 mV. Calculated by The UK Post.

Even a full bridge only gives a few millivolts, so the signal goes through an amplifier and an analogue-to-digital converter. Load cells are rated in millivolts per volt (mV/V): a common figure is 2 mV/V, meaning 10 mV out at full load with 5 V in. Hobbyists often pair a cheap load cell with an HX711 amplifier board and an Arduino or Raspberry Pi to build their own scales.

How a Strain Gauge Is Fitted

A gauge is only as good as its bond. If the glue creeps or the surface is dirty, the gauge measures the glue, not the part. Installation follows the same basic steps everywhere, from university labs to aerospace test houses:

Fitting a foil strain gauge, step by step

STEP 1
Prepare the surface
Sand, degrease and clean the spot until it is bright and dust-free.
STEP 2
Mark the direction
Scribe light lines so the grid lines up with the strain you want.
STEP 3
Bond the gauge
Glue it with strain gauge adhesive and press it flat while it cures.
STEP 4
Wire it up
Solder leads to the tabs and anchor the cable so it cannot pull.
STEP 5
Protect it
Coat it against moisture and knocks, especially outdoors.
STEP 6
Zero and check
Balance the bridge, then test with a known load.

If you are fitting your first gauges, my advice is to practise on a scrap strip of aluminium before touching the real part, and fit one more gauge than you need. Surface preparation feels tedious, but it is where most bad readings start, and a gauge cannot be peeled off and reused.

Types of Strain Gauge

TypeHow it worksStrengthsWatch out for
Metal foil (the standard)Etched foil grid on a polymer carrierCheap, stable, many sizes and patternsLow output; needs a good bond
Bonded wireFine wire looped on a backing; the original 1938 designHigh-temperature versions still usedLargely replaced by foil
Semiconductor (silicon)Piezoresistive silicon elementGauge factor around 50 to 100 times higher than foil; tinyVery temperature-sensitive and less linear
RosetteTwo or three grids at set angles on one carrierMeasures strain when you do not know its directionNeeds extra channels and calculation
WeldableGauge pre-mounted on a metal shim and spot-welded onQuick to fit outdoors on steel structuresLarger, less precise
Fibre optic (fibre Bragg grating)Light reflected from a grating in an optical fibre shifts with strainImmune to electrical noise; many sensors on one fibre; long distancesExpensive interrogator equipment

Where You Meet Strain Gauges in Everyday Life

Chances are you use a strain gauge regularly without knowing it:

  • Bathroom and kitchen scales: digital scales use load cells, metal blocks shaped to bend slightly under weight, with strain gauges bonded where the bending is greatest. A typical bathroom scale has one in each foot.
  • Supermarket tills and post office counters: the scales used to sell by weight are load-cell scales. Scales used for trade in the UK must meet legal metrology rules and be checked by trading standards, which is why they carry approval markings.
  • Weighbridges and lorry checks: heavy-duty load cells weigh whole vehicles at quarries, ports, waste sites and enforcement checks.
  • Cycling power meters: the power meters in many crank arms, pedals and hubs measure how much the metal flexes under each pedal stroke.
  • Torque wrenches and screwdrivers: electronic torque tools read the twist in their shaft with strain gauges. If you have ever stripped a screw by over-tightening it, our guide to removing a stripped screw explains how to rescue it.
  • Pressure sensors: many car, boiler and medical pressure sensors are strain gauges on a thin diaphragm that bulges under pressure.
  • 3D printers: some home 3D printers use a load cell in the print head to level the bed automatically; see our guide to PLA+ filament for the most popular material they print.
Two load cells from a bathroom scale, one with its strain gauge exposed
Load cells from a budget bathroom scale. On the right, the protective coating is removed to show the small strain gauge bonded where the metal bends most. Photo: Raimond Spekking, Wikimedia Commons, CC BY-SA 4.0.

Strain Gauges in Engineering and Safety

The serious work happens out of sight. Aircraft makers cover test airframes with thousands of gauges and load them until they break, to prove a design is safe. Car makers use them in crash and durability testing; Formula 1 teams use them to measure the loads on suspension parts.

In civil engineering, gauges help monitor ageing structures. London’s Hammersmith Flyover, a 1960s prestressed concrete viaduct, has been the subject of published monitoring studies in which strain gauges and tilt sensors on the piers worked alongside acoustic sensors listening for breaking steel wires inside the concrete. The researchers found that no single sensor told the whole story, and that visual inspection was still needed to confirm problems, which is a useful reminder that sensors support engineers rather than replace them. As monitoring data grows, it increasingly feeds into building and asset records; our guide to digital facilities management explains the UK duties driving that shift.

A Short History, with a British Twist

  1. 1833Samuel Hunter Christie publishes the bridge circuit in London.
  2. 1843Charles Wheatstone popularises it; the name “Wheatstone bridge” sticks.
  3. 1856Lord Kelvin reports that metals change resistance when strained.
  4. 1938Edward Simmons (Caltech) and Arthur Ruge (MIT) independently invent the bonded wire gauge.
  5. 1940sThe “SR-4” gauge, named after Simmons and Ruge, goes into mass production.
  6. Early 1950sSaunders-Roe on the Isle of Wight develops the foil strain gauge.
  7. 1950s–60sSemiconductor gauges and foil load cells arrive; foil becomes the standard.
  8. TodayFoil, silicon and fibre-optic gauges in everything from scales to bridges.

The British contribution is bigger than most histories admit. At Saunders-Roe in East Cowes on the Isle of Wight, engineer Peter Scott Jackson saw that the copper-etching process used to make printed circuit boards could produce a strain gauge grid far more consistently than winding wire. Working with Technograph Printed Circuits, the company produced the first foil strain gauges in the early 1950s, partly because wire gauges kept failing during vibration tests on helicopter rotor blades. The new gauges were used on the airframe of the giant Saunders-Roe Princess flying boat. Foil is now the standard design worldwide.

Saunders-Roe SR.45 Princess flying boat taxiing on the water in the early 1950s
The Saunders-Roe SR.45 Princess flying boat, built at East Cowes. Its airframe was one of the first to be tested with foil strain gauges. Photo: San Diego Air and Space Museum Archives, Wikimedia Commons, public domain.

What Goes Wrong: Common Sources of Error

  • Temperature: heat changes the resistance of the foil and makes the part expand, both of which look like strain. Engineers use “self-temperature-compensated” gauges matched to steel or aluminium, half or full bridges, or a dummy gauge on an unloaded piece of the same material.
  • Poor bonding: dirt, grease or the wrong adhesive gives readings that drift or creep.
  • Long lead wires: the resistance of the wires adds to the gauge; three-wire connections cancel much of this.
  • Moisture: damp gets under the carrier and causes drift, so outdoor gauges need protective coatings.
  • Electrical noise: millivolt signals pick up interference from motors and mains cables; screened cable helps.
  • Fatigue and overload: gauges have a life and a maximum strain; strain them too far or too often and they crack.

Engineers who work with gauges in the field are candid about this. A review of the Hammersmith Bridge engineering reports noted that field-bonded strain gauges are not uncommonly prone to spurious readings. Good practice is to sanity-check every result against a simple hand calculation.

Learning About Strain Gauges in the UK

Strain gauges come up in A-level physics and engineering courses, BTEC and T Level engineering qualifications, and almost every mechanical, civil and aerospace engineering degree. If you want to experiment at home, a kitchen-scale load cell, an HX711 board and a microcontroller cost well under £20 together from UK hobby electronics shops, and are an excellent first project. For a broader, readable introduction to engineering ideas like this, our review of a Popular Mechanics subscription looks at whether the magazine is worth it for UK readers.

Frequently Asked Questions

What does a strain gauge measure?

It measures strain: how much a surface stretches or compresses. From that, engineers calculate force, weight, pressure, torque or stress.

How does a strain gauge work in simple terms?

It is a fine metal grid glued to a part. When the part stretches, the grid gets longer and thinner and its resistance rises; when it is squeezed, the resistance falls. A bridge circuit turns that change into a voltage.

What is a gauge factor?

The ratio of the fractional change in resistance to the strain. Standard foil gauges have a gauge factor of about 2; semiconductor gauges are far higher.

Why are strain gauges used in a Wheatstone bridge?

Because the resistance change is tiny, often under one ohm. The bridge converts it into a small voltage that can be amplified and measured accurately, and can cancel temperature effects.

What is the difference between a strain gauge and a load cell?

A strain gauge is the sensing element. A load cell is a complete force sensor: a shaped metal body with strain gauges, usually four in a full bridge, bonded to it and calibrated to read force or weight.

What are common strain gauge resistances?

120 ohms and 350 ohms are the most common, with 1,000 ohms also used. Higher resistance means less heating and less effect from lead wires.

Can a strain gauge be reused?

No. Once bonded, it cannot be removed without damage. Each gauge is fitted once.

How much does a strain gauge cost in the UK?

A single general-purpose foil gauge costs from about £9 plus VAT from UK suppliers, with precision gauges costing more. Hobby load cells can be bought for a few pounds.

Who invented the strain gauge?

The bonded wire strain gauge was invented independently in 1938 by Edward Simmons at Caltech and Arthur Ruge at MIT. The foil gauge was developed in Britain at Saunders-Roe in the early 1950s.

Is it “strain gauge” or “strain gage”?

Both refer to the same thing. “Gauge” is the British spelling; “gage” is a common American engineering spelling, used by some manufacturers.

Final Thoughts

Strain gauges are one of engineering’s quiet success stories: a few pounds of foil and glue that tell us how hard a bridge, a wing or a bathroom scale is working. The idea is simple, stretch it and the resistance rises, but getting good numbers depends on careful fitting, the right bridge and a healthy suspicion of any reading that looks too neat. If you are curious, a cheap load cell project is the best way to see it for yourself.

Sources: Wikipedia articles on the strain gauge, Wheatstone bridge, Samuel Hunter Christie, Edward E. Simmons and Arthur C. Ruge; Micro-Measurements technical history notes on the Saunders-Roe foil gauge; Aircraft Engineering (1952), “The Saunders-Roe Technograph foil strain gauge”; Webb et al., Journal of Bridge Engineering (2014), on Hammersmith Flyover monitoring; GOV.UK, Hammersmith Bridge engineering reports; RS Components UK product listings (prices checked November 2026).

The UK Post Daily Newsletter

Top headlines, in-depth analysis and opinions — straight to your inbox.

↑
Scroll to Top